10,905 research outputs found

    Low-level finite state control of knee joint in paraplegic standing

    Get PDF
    Low-level finite state (locked-unlocked) control is compared with open-loop stimulation of the knee extensor muscles in functional electrical stimulation (FES) induced paraplegic standing. The parameters were: duration of standing, relative torque loss in knee extensor muscles, knee angle stability, average stimulus output and average arm effort during standing. To investigate the impact of external mechanical conditions on controller performance, experiments were performed both under the condition of a freely moving ankle joint and of a mechanically stabilized ankle joint. Finite state control resulted in a 2.5 to 12 times increase of standing duration or in a 1.5 to 5 times decrease of relative torque loss in comparison with open-loop stimulation. Finite state control induced a limit cycle oscillation in the knee joint. Average maximum knee flexion was 6.2° without ankle bracing, and half that value with ankle bracing. Average arm support was 13.9 and 7.5% of the body weight without and with ankle bracing respectively

    Convexities related to path properties on graphs; a unified approach

    Get PDF
    Path properties, such as 'geodesic', 'induced', 'all paths' define a convexity on a connected graph. The general notion of path property, introduced in this paper, gives rise to a comprehensive survey of results obtained by different authors for a variety of path properties, together with a number of new results. We pay special attention to convexities defined by path properties on graph products and the classical convexity invariants, such as the Caratheodory, Helly and Radon numbers in relation with graph invariants, such as clique numbers and other graph properties.

    Patient-specific modelling of the cerebral circulation for aneurysm risk assessment

    Get PDF
    Cerebral aneurysms are localised pathological dilatations of cerebral arteries, most commonly found in the circle of Willis. Although not all aneurysms are unstable, the major clinical concern involved is the risk of rupture. High morbidity and mortality rates are associated with the haemorrhage resulting from rupture. New indicators of aneurysm stability are sought, since current indicators based on morphological factors have been shown to be unreliable. Haemodynamical factors are known to be relevant in vascular wall remodelling, and therefore believed to play an important role in aneurysmdevelopment and stability. Studies suggest that intra-aneurysmal wall shear stress and flow patterns, for example, are candidate parameters in aneurysm stability assessment. These factors can be estimated if the 3D patient-specific intra-aneurysmal velocity is known, which can be obtained via a combination of in vivo measurements and computational fluid dynamics models. The main determinants of the velocity field are the vascular geometry and flow through this geometry. Over the last decade the extraction of the vascular geometry has become well established. More recently, there has been a shift of attention towards extracting boundary conditions for the 3D vascular segment of interest. The aim of this research is to improve the reliability of the model-based representation of the velocity field in the aneurysmal sac. To this end, a protocol is proposed such that patient-specific boundary conditions for the 3D segment of interest can be estimated without the need for added invasive procedures. This is facilitated by a 1D wave propagation model based on patient-specific geometry and boundary conditions measured non-invasively in more accessible regions. Such a protocol offers improved statistical reliability owing to the increased number of patients that can participate in studies aiming to identify parameters of interest in aneurysm stability assessment. In chapter 2 the intra-aneurysmal velocity field in an idealised aneurysm model is validated with particle image velocimetry experiments, after which the flow patterns are evaluated using a vortex identification method. Chapter 3 describes a 1D model wave propagation model of the cerebral circulation with a patient-specific vascular geometry. The resulting flow pulses at the boundaries of the 3D segment of interest are compared to those obtained with a patient-generic geometry. The influence of these different boundary conditions on the 3D intra-aneurysmal velocity field is evaluated in chapter 4 by prescribing the end-diastolic flows extracted from the 1D models. In order to measure blood flow with videodensitometric methods, an injection of contrast agent is required. The effect of this injection on the flow of interest is assessed in chapter 5. In chapter 6, pressure measurements in the internal carotid are used to evaluate the variability of pressure waveform and its effect on the boundary conditions for the 1D model. Finally, a protocol for full patient-specific modelling is discussed in chapter 7

    Resonant diaphragm pressure measurement system with ZnO on Si excitation

    Get PDF
    The principle of measuring pressure by means of a resonant diaphragm has been studied. An oscillator consisting of an integrated amplifier with a piezoelectrically driven diaphragm in its feedback loop has been built. The oscillator frequency is accurately proportional to the square of the pressure in the range of 60 to 130 Torr.\ud The frequency range is 1324 to 1336 Hz (this range being limited by a spurious mode which could be suppressed by better processing) for a 25 mm diameter diaphragm made of a silicon wafer and with PZT ceramics as driver and receptor. We have made an integrated version (1 × 1 mm2) of a square resonant diaphragm pressure guage by selective etching of (1 0 0) planes with ethylenediamine. The piezoelectric driving materials was sputtered zinc oxide. A driver was deposited midway between the bending point and the point of greatest curvature.\ud A receptor was located at a symmetrical position to give a optimum transfer condition.\ud The integrated current amplifier had a low impedance differential input stage, two gain cells and a high impedance output stage. These electrical conditions ensured maximum elastic freedom of the diaphragm. A digital circuit in I2L technology has been designed and made with eight-bit parallel read out of the frequency. This circuit may be directly connected to a microprocessor. The whole system contains the sensor chip, the analog amplifier chip and the digital chip, all in compatible technology.\ud \u

    Adsorbent filled membranes for gas separation. Part 1. Improvement of the gas separation properties of polymeric membranes by incorporation of microporous adsorbents

    Get PDF
    The effect of the introduction of specific adsorbents on the gas separation properties of polymeric membranes has been studied. For this purpose both carbon molecular sieves and zeolites are considered. The results show that zeolites such as silicate-1, 13X and KY improve to a large extent the separation properties of poorly selective rubbery polymers towards a mixture of carbon dioxide/methane. Some of the filled rubbery polymers achieve intrinsic separation properties comparable to cellulose acetate, polysulfone or polyethersulfone. However, zeolite 5A leads to a decrease in permeability and an unchanged selectivity. This is due to the impermeable character of these particles, i.e. carbon dioxide molecules cannot diffuse through the porous structure under the conditions applied. Using silicate-1 also results in an improvement of the oxygen/nitrogen separation properties which is mainly due to a kinetic effect. Carbon molecular sieves do not improve the separation performances or only to a very small extent. This is caused by a mainly dead-end (not interconnected) porous structure which is inherent to their manufacturing process

    Spiral order by disorder and lattice nematic order in a frustrated Heisenberg antiferromagnet on the honeycomb lattice

    Full text link
    Motivated by recent experiments on Bi3_3Mn4_4O12_{12}(NO3_3), we study a frustrated J1J_1-J2J_2 Heisenberg model on the two dimensional (2D) honeycomb lattice. The classical J1J_1-J2J_2 Heisenberg model on the two dimensional (2D) honeycomb lattice has N\'eel order for J2J1/6J_2 J_1/6, it exhibits a one-parameter family of degenerate incommensurate spin spiral ground states where the spiral wave vector can point in any direction. Spin wave fluctuations at leading order lift this accidental degeneracy in favor of specific wave vectors, leading to spiral order by disorder. For spin S=1/2S=1/2, quantum fluctuations are, however, likely to be strong enough to melt the spiral order parameter over a wide range of J2/J1J_2/J_1. Over a part of this range, we argue that the resulting state is a valence bond solid (VBS) with staggered dimer order - this VBS is a nematic which breaks lattice rotational symmetry. Our arguments are supported by comparing the spin wave energy with the energy of the dimer solid obtained using a bond operator formalism. Turning to the effect of thermal fluctuations on the spiral ordered state, any nonzero temperature destroys the magnetic order, but the discrete rotational symmetry of the lattice remains broken resulting in a thermal analogue of the nematic VBS. We present arguments, supported by classical Monte Carlo simulations, that this nematic transforms into the high temperature symmetric paramagnet via a thermal phase transition which is in the universality class of the classical 3-state Potts (clock) model in 2D. We discuss the possible relevance of our results for honeycomb magnets, such as Bi3_3M4_4O12_{12}(NO3_3) (with M=Mn,V,Cr), and bilayer triangular lattice magnets.Comment: Slightly revise

    A model for the orientational ordering of the plant microtubule cortical array

    Full text link
    The plant microtubule cortical array is a striking feature of all growing plant cells. It consists of a more or less homogeneously distributed array of highly aligned microtubules connected to the inner side of the plasma membrane and oriented transversely to the cell growth axis. Here we formulate a continuum model to describe the origin of orientational order in such confined arrays of dynamical microtubules. The model is based on recent experimental observations that show that a growing cortical microtubule can interact through angle dependent collisions with pre-existing microtubules that can lead either to co-alignment of the growth, retraction through catastrophe induction or crossing over the encountered microtubule. We identify a single control parameter, which is fully determined by the nucleation rate and intrinsic dynamics of individual microtubules. We solve the model analytically in the stationary isotropic phase, discuss the limits of stability of this isotropic phase, and explicitly solve for the ordered stationary states in a simplified version of the model.Comment: 15 pages, 5 figure

    Preparation of zeolite filled glassy polymer membranes

    Get PDF
    The incorporation of zeolite particles in the micrometer range into polymeric matrices was investigated as a way to improve the gas separation properties of the polymer materials used in the form of membranes. The adhesion between the polymer phase and the external surface of the particles appeared to be a major problem in the preparation of such membranes when the polymer is in the glassy state at room temperature. Various methods were investigated to improve the internal membrane structure, that is, surface modification of the zeolite external surface, preparation above the glass-transition temperature, and heat treatment. Improved structures were obtained as observed by scanning electron microscopy, but the influence on the gas separation properties was not in agreement with the observed structural improvements
    • …
    corecore